Fire Risk Assessment
| Premises | 2nd floor, 10 King Street, Nottingham NG1 2AS |
| Type | Office |
| Responsible person | Example Accountants Ltd (managing director) |
| Assessed by | Office manager |
| Date | 1 October 2026 |
1. Legal basis
Regulatory Reform (Fire Safety) Order 2005. Applies to non-domestic premises and the common parts of blocks of flats and HMOs. Also consider the Fire Safety Act 2021; in England, consider the Fire Safety (England) Regulations 2022 where applicable. Confirm the enforcing authority and any local licensing conditions.
People at risk: 12 staff and up to 5 visitors
2. Significant findings and action plan
| Area | Finding | Action required | Priority | Owner / date done |
|---|---|---|---|---|
| Firefighting equipment | An extinguisher may be unavailable or unserviceable. | Arrange replacement or competent service and keep access clear. | medium | |
| Management, training and drills | The evacuation plan has not been tested in practice. | Plan a representative drill, record performance and correct shortcomings. | medium | |
| Maintenance and testing | Emergency-light operation is not routinely checked. | Introduce a monthly functional test as typical guidance; confirm the method and interval with the standard and contractor. | medium |
3. Arrangements confirmed as in place
| Sources of ignition | Is smoking prohibited indoors and restricted to a safe external area with suitable metal bins? | Yes |
| Sources of ignition | Are plugs, leads, sockets and appliances free from visible damage, overloading and unsafe adaptors? | Yes |
| Sources of ignition | Is the fixed electrical installation inspected and maintained at an interval set by a competent electrician? | Yes |
| Sources of ignition | Are portable heaters stable, guarded where needed, and kept clear of combustibles? | Yes |
| Sources of ignition | Are cooking appliances, extraction systems and filters kept clean and used away from combustibles? | Yes |
| Sources of ignition | Is hot work avoided or controlled by a permit, fire watch and post-work check? | not undertaken |
| Sources of ignition | Are external bins, waste and combustible storage secured away from the building and ignition sources? | Yes |
| Sources of ignition | Are contractors told the fire precautions and controlled when their work introduces ignition sources? | Yes |
| Fuel and storage | Is combustible stock limited to working quantities and stored away from ignition sources? | Yes |
| Fuel and storage | Are flammable liquids kept in closed containers, in minimum quantities and in suitable fire-resisting storage? | none |
| Fuel and storage | Are LPG and other gas cylinders absent or stored upright, secured and in a suitable ventilated location? | none |
| Fuel and storage | Are aerosols kept away from heat and limited to reasonable quantities? | Yes |
| Fuel and storage | Are displays, decorations, upholstered items and wall linings in good condition and suitable for their location? | Yes |
| Fuel and storage | Are boiler, electrical and plant rooms free from unrelated combustible storage? | Yes |
| Fuel and storage | Is waste removed frequently before it accumulates? | Yes |
| Fuel and storage | Could dangerous substances make a fire start or develop more rapidly? | No |
| People at risk | Are lone workers, cleaners and people present outside normal hours included in the arrangements? | Yes |
| People at risk | Have individual evacuation needs been identified without relying on fire and rescue services? | Yes |
| People at risk | Are visitors and members of the public given clear warning and direction? | Yes |
| People at risk | Are young persons and inexperienced workers specifically considered? | none present |
| People at risk | Does anyone sleep anywhere other than the common parts covered by this assessment? | No |
| People at risk | Could any occupant need assisted evacuation because of mobility, sensory, cognitive or temporary impairment? | No |
| People at risk | Have people in neighbouring or shared premises who could be affected been considered? | Yes |
| Fire detection and alarm | Is the alarm and detection system suitable for the layout, use and people at risk? | Yes |
| Fire detection and alarm | Can a person readily raise the alarm from occupied areas and near exits? | Yes |
| Fire detection and alarm | Can the alarm be heard clearly in every occupied area, including toilets and noisy rooms? | Yes |
| Fire detection and alarm | Where hearing-impaired people may be alone, are suitable visual or vibrating warnings provided? | not needed |
| Fire detection and alarm | Is automatic detection provided where a fire could develop unnoticed or affect escape routes? | Yes |
| Fire detection and alarm | Is the alarm panel accessible, labelled and understood by nominated staff? | Yes |
| Fire detection and alarm | Are faults, isolations and unwanted alarms recorded and corrected promptly? | Yes |
| Fire detection and alarm | Are any door releases, shutters, lifts or plant shutdowns linked to the alarm tested as part of the system? | none |
| Means of escape | Are the number, width and arrangement of escape routes suitable for occupancy and travel distance? | Yes |
| Means of escape | Are corridors, stairs and exits kept clear at all times? | Yes |
| Means of escape | Can final exits be opened immediately without a key or special knowledge while occupied? | Yes |
| Means of escape | Do doors on crowded or higher-risk routes open in the direction of escape where required? | Yes |
| Means of escape | Where one route could be affected by a single fire, is an independent alternative route available? | not required |
| Means of escape | Do shutters, access controls and security doors fail safe or have a reliable emergency override? | none |
| Means of escape | Are external escape routes, gates and assembly access clear, lit where needed and usable in bad weather? | Yes |
| Means of escape | Are inner rooms, dead ends and basement or upper-floor escape arrangements acceptably protected? | none |
| Emergency lighting | Is emergency escape lighting provided where normal lighting failure would leave routes unsafe? | Yes |
| Emergency lighting | Does emergency lighting cover stairs, changes of direction, exits, call points, firefighting equipment and external routes where needed? | Yes |
| Emergency lighting | Are larger open areas provided with anti-panic lighting where needed? | not needed |
| Emergency lighting | Are internally illuminated or externally lit escape signs visible during power failure? | Yes |
| Emergency lighting | Are luminaires and indicators present, unobscured and free from visible damage? | Yes |
| Emergency lighting | Can the system be safely tested without creating avoidable risk? | Yes |
| Emergency lighting | Are emergency-lighting tests and defects recorded? | Yes |
| Emergency lighting | Has a competent person confirmed the system duration is suitable for the evacuation strategy and premises? | Yes |
| Fire safety signs and notices | Are escape routes and exits clearly signed wherever the route is not obvious? | Yes |
| Fire safety signs and notices | Do directional arrows lead continuously to a final exit without ambiguity? | Yes |
| Fire safety signs and notices | Are fire doors marked with the appropriate keep-shut or keep-locked notice? | Yes |
| Fire safety signs and notices | Are extinguishers, call points and alarm controls clearly identified where not obvious? | Yes |
| Fire safety signs and notices | Are lifts that must not be used in a fire clearly marked? | no lift |
| Fire safety signs and notices | Are concise fire-action notices displayed and consistent with the current procedure? | Yes |
| Fire safety signs and notices | Is the assembly point identified where one is used? | Yes |
| Fire safety signs and notices | Are instructions understandable to the people present, including where language or disability affects comprehension? | Yes |
| Firefighting equipment | Has a competent person selected suitable types and quantities of extinguishers for the risks? | Yes |
| Firefighting equipment | Are extinguishers conspicuous, accessible and normally positioned on escape routes near exits? | Yes |
| Firefighting equipment | Are cooking-oil and electrical risks provided with suitable equipment without encouraging unsafe firefighting? | not applicable |
| Firefighting equipment | Where a fire blanket is provided, is it accessible, correctly mounted and suitable for its intended use? | none |
| Firefighting equipment | Are hose reels absent or, if present, included in competent inspection and staff arrangements? | none |
| Firefighting equipment | Are nominated staff told that extinguishers are for small fires only and escape takes priority? | Yes |
| Firefighting equipment | Are specialist risks such as lithium batteries, flammable metals or gas cylinders present? | No |
| Compartmentation and fire doors | Are fire-resisting walls, floors and ceilings free from visible holes, gaps or damage? | Yes |
| Compartmentation and fire doors | Are service penetrations around cables, pipes and ducts suitably fire stopped? | Yes |
| Compartmentation and fire doors | Do fire doors close fully into the frame from any position without sticking? | Yes |
| Compartmentation and fire doors | Are fire-door leaves, frames, glazing, hinges, seals and gaps visibly sound? | Yes |
| Compartmentation and fire doors | Are fire doors kept shut or held open only by a suitable alarm-linked device? | Yes |
| Compartmentation and fire doors | Are locked fire-resisting cupboards, risers and plant rooms controlled and kept closed? | Yes |
| Compartmentation and fire doors | Have concealed voids, roof spaces and recent alterations been considered for fire stopping? | Yes |
| Compartmentation and fire doors | Is the required fire-resistance strategy clear from reliable plans, records or competent assessment? | Yes |
| Housekeeping | Are escape routes, stairs and fire doors free from storage and waste? | Yes |
| Housekeeping | Are floors, work areas and storage spaces kept clean and orderly? | Yes |
| Housekeeping | Is there an end-of-day check for cooking, heaters, electrical equipment, waste and fire doors? | Yes |
| Housekeeping | Are batteries and devices charged on suitable surfaces, with approved equipment and away from escape routes? | Yes |
| Housekeeping | Are oily, greasy or heat-affected cloths and laundry handled to prevent self-heating? | none |
| Housekeeping | Are deliveries and temporary stock prevented from blocking exits or alarm equipment? | Yes |
| Housekeeping | Is vegetation, packaging and waste controlled around the building perimeter? | Yes |
| Housekeeping | Are routine housekeeping inspections assigned and recorded? | Yes |
| Management, training and drills | Is the responsible or dutyholder person identified and are other responsible persons coordinated? | Yes |
| Management, training and drills | Is there a current emergency plan covering alarm, evacuation, calling the fire service and assembly? | Yes |
| Management, training and drills | Do staff receive fire instruction at induction and when arrangements change? | Yes |
| Management, training and drills | Are enough trained people available to implement the plan whenever the premises is occupied? | Yes |
| Management, training and drills | Is there a workable method to account for staff and visitors without delaying escape? | Yes |
| Management, training and drills | Can someone give the fire service reliable information about hazards, missing people and access? | Yes |
| Management, training and drills | Is the assessment reviewed after changes, fire, near miss, enforcement concern or evidence it may no longer be valid? | Yes |
| Maintenance and testing | Is the fire alarm normally tested weekly from a different call point and the result recorded? | Yes |
| Maintenance and testing | Is the alarm competently serviced at the interval specified for the system, commonly every six months? | Yes |
| Maintenance and testing | Is emergency lighting given a competent full-duration test at least annually? | Yes |
| Maintenance and testing | Are extinguishers visually checked routinely, commonly monthly, and defects acted on? | Yes |
| Maintenance and testing | Are extinguishers maintained by a competent person, normally annually? | Yes |
| Maintenance and testing | Are fire doors checked routinely, with higher frequency for high-use or residential common-area doors? | Yes |
| Maintenance and testing | Are test, service, defect and repair records complete and readily available? | Yes |
Scope limits
This assessment format is for small, simple premises. Use a competent fire risk assessor instead for:
- Any sleeping accommodation assessment beyond the common parts of a small HMO or small block of flats.
- Care homes, hospitals, healthcare premises, prisons, secure premises or premises where occupants may need assisted evacuation.
- Hotels, hostels, large HMOs, complex sleeping risks or premises with significant numbers of unfamiliar sleeping occupants.
- High-rise residential buildings and work requiring assessment under the Building Safety Act 2022 or higher-risk building regime.
- Large, complex, multi-occupied, underground or unusual premises, or premises with engineered fire-safety solutions.
- Premises storing or using significant quantities of dangerous substances, explosives, highly flammable materials or oxygen-enriched atmospheres.
- Premises with combustible cladding, unresolved compartmentation concerns, complex smoke control, evacuation lifts or stay-put strategies requiring validation.
- Any case involving repeated unwanted alarms, enforcement action, a recent serious fire, uncertain structural fire protection or doubt about means of escape.
- Any assessment outside the competence of the person completing it. Refuse generation and recommend a competent fire risk assessor or fire engineer.
Review
Review this assessment at least annually and whenever the premises, use or occupancy changes, or after a fire or near miss.
| Name | Signature | Date |
|---|---|---|
Drafted with SitePaper from information supplied by Example Accountants Ltd. The duty holder remains responsible for its contents and must have it reviewed by a competent person before relying on it. Contains public sector information licensed under the Open Government Licence v3.0.